Options and Accessories for UDS

Configuration

  • Chase style – Standard flat top, optional peak top available.
  • Riser termination –  An adjustable height collar (78 to 84 inch) is provided. If required, an optional riser extension is available at specified heights
  • Special configurations – are available, please contact your Accurex representative for details

Gas

  • Main ball valve – on incoming service to turn gas off at the unit
  • Gas drop size – 1-inch diameter drops available. Alternating 0.75 and 1.25 are standard and placed every 12 in. capped for future use if not being used.
  • Ball valves – available sizes are .5, .75, 1, and 1.25 inches.
  • Quick disconnect hoses – provide an easy method of connecting or disconnecting gas lines (available in 48, 60, and 72 inch lengths), optional super swivel available.
  • Restraining cables – prevent cooking equipment from being moved without disconnecting the gas line
  • Fire system gas valve – mechanical or electric with manual reset gas valves can be mounted in the unit to turn off gas in fire mode
  • Battery backup for gas solenoid – available for your gas utilities

Water

  • Main ball valves – on incoming service to turns water off at the unit
  • Hot and cold water drops –in 0.75 inch diameter and are placed every 24 inches
  • Ball valves – available sizes are .25, 375, .5, and .75 inch for shut off at each connection along the chase
  • Water hoses – available in lengths of 48, 60 or 72 inches
  • Gauges – are available for either pressure/temperature or pressure only
  • Fill faucet – with 60 inch hose
  • Water filters –  available in single appliance and multiple appliance styles
  • Shock arrestors – to prevent water hammering that typically occurs when the water is shut off
  • Pressure reducing valve – iused when the water pressure entering the UDS is too high. The reducer valve reduces the pressure to an appropriate level (typically 40-60 psi)
  • Hand sink – (mounted on the riser) is available. Sink is 12 inches wide
  • Hose reel assembly – Mounted on one of the risers is available for auxiliary hoses

Electrical

Primary Electrical Service – Choose from panel board or point of use breakers. Main breaker and branch breakers are provided with primary electrical service (see table below for available sizes)

Breaker

Voltage

Phase

Min Size (Amp)

Max Size (Amp)

Main

208

3

40

400

Branch

120

1

20

50

Branch

208

1

20

70

Branch

208

3

20

125

 

Electrical receptacles – are 120 V or 208 V based on need and the receptacles NEMA configuration is straight blade with an available twist lock option in 120/1 - 20A GFCI (GFCI not available with twist lock), Optional cord set also available.
Controls – for the primary electrical service option include optional status lights, fire system connection, optional light or fan (switches), gas solenoid control panel (with a solenoid gas valve), optional emergency shut down and pre-wired tempering switch (if required)

 

Secondary Electrical Service – Choose from panel board or point of use breakers. Main breaker and branch breakers, including optional ground fault protection, is provided with secondary electrical service. See table for available sizes

 

Breaker

Voltage

Phase

Min Size (Amp)

Max Size (Amp)

Main

480 or 208

3

40

400

Branch

120

1

20

50

Branch

208

1

20

70

Branch

208

3

20

125

Branch

480

3

20

100

Additional Utilities and Options

  • Prison package
  • Steam/condensate system
  • Chilled water line with insulation
  • Compressed air line
  • Gasketed construction
  • Weatherproof receptacle/switch covers
  • While-in-use receptacle covers
  • 12-inch by 12-inch viewing window in riser
  • Hinged access doors
  • Water filter bracket on chase
  • 10 ft. conduit for wiring to hood lights
  • Ground fault equipment protection
  • XFCC mounted in riser
  • Variable volume system mounted in riser
  • Temperature interlock mounted in riser

Please contact your Accurex representative for more information

 